93309,C94012,1982,01,01,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Station opened. 93309,C94012,1986,03,31,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Station closed. 93309,C94012,1991,10,31,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Q19121436 reopened. 93309,C94012,1993,06,16,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Routine maintenance and calibration visit. The station was in good repair with a well maintained enclosure. The lightning counter earthing bolt had corroded and was replaced. The following sensors were replaced routinely: Vaisala anemometer; Vaisala vane; Vaisala barometer; Rotronics humidity; Licor pyranometer and lightning counter. 93309,C94012,1994,05,25,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Routine maintenance and calibration visit. Well maintained enclosure and station in good order. Routine replacement of the following sensors: anemometer; vane; barometer; humidity; Sutron GPIO; dry bulb and grass minimum. 93309,C94012,1995,11,06,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Routine maintenance and calibration visit. The enclosure had been mowed but weeds needed spraying. The following sensors/units were replaced routinely: anemometer; vane; barometer; humidity; pyranometer; lightning counter; raingauge; battery. 93309,C94012,1996,09,17,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Routine maintenance and calibration visit. Station in good order with well maintained enclosure. The following sensors were routinely replaced: anemometer; vane; barometer; humidity; Sutron GPIO. The screen was replaced. A new modem was installed. 93309,C94012,1997,07,17,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Routine maintenance and calibration visit. Wind speed and direction; humidity; lightning counter; sol rad; air temp and grass min all routinely replaced. 93309,C94012,1998,07,16,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Routine maintenance and calibration visit. Wind speed and direction; humidity and raingauge all routinely replaced. 93309,C94012,2000,02,22,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Annual maintenance and calibration visit. Wind speed and direction; humidity; barometer; sol rad; lightning counter; air and grass temp all routinely replaced. 93309,C94012,2001,02,02,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Humidity replaced as over ranging. 93309,C94012,2001,03,06,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Annual maintenance and calibration visit. Wind speed and direction; humidity and barometer all routinely replaced. 93309,C94012,2002,02,18,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Replaced under reading humidity probe. 93309,C94012,2002,03,07,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Annual maintenance and calibration visit. Wind speed and direction; humidity; pressure; lightning counter and solar radiation all routinely replaced. The raingauge was counting twice on one side so was replaced. 93309,C94012,2002,04,30,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Rotronic replaced (20% low). Reset Sutron base year. 93309,C94012,2002,08,06,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Faulty Rotronic replaced with HPM45 93309,C94012,2002,09,10,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,New software installed. 93309,C94012,2003,03,19,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,HMP probe replaced. 93309,C94012,2003,04,14,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Annual maintenance & calibration. Replaced TT; TG; DPA21; GP10; WAA; WAV. Fit new grass probe. 93309,C94012,2004,04,14,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Station not dialing out. Replaced PSM. All OK. 93309,C94012,2004,04,29,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Annual maintenance and calibration visit. Wind speed and direction; humidity; pressure and solar radiation routinely replaced. 93309,C94012,2004,06,25,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,No data out of ACNZ. CPM locked up. Replaced & loaded software. OK. 93309,C94012,2004,09,09,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Replaced Licor. Loaded 3ARTU_51 software. Realigned earth cableway from sensor cable. 93309,C94012,2005,02,06,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Humidity going over 100%. New probe sent to contactor. 93309,C94012,2005,03,01,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Upgraded software to 3ERTU_10 & fit harvest modem. Station converted to 1 minute & dial up modem disconnected. 93309,C94012,2005,04,20,93309,C94012,39,00,22,S,174,10,42,E,New Zealand Meteorological Service,NEW PLYMOUTH AWS,30,Annual service. Replaced OTA; WAA; WAV; GPIO; DPA21; Harvest & Battery. Upgrade Sutron cabinet & Harvest cable. New photographs taken.