Message:
You are not authorized to view all fields; at least one has been removed.

Event Details

Station: NC Asheville 13 S NC Mtn. Horticultural Crops Res. Ctr. (Backlund Site)
Event Type: Maintenance - Annual (Completed)
Event Date: Thu Feb 22 20:00:00 UTC 2007
Notes: null
EventId: 965
This display shows all new and previous values for all fields in the database for this station as of the addition of this event.
item approved This event has completed QC
previous event next event
Previous Value (prior to event) New Value (if changed)

General Site Information
Name: NC Mtn. Horticultural Crops Res. Ctr. (Backlund Site)
State: NC
Location: Asheville
Vector: 13 S
County: Henderson
Country: US
Latitude: 35.4185
Longitude: -82.5567
Elevation: 2103
Offset: -5
Timezone: EST
Climate Division: 01
Commission Code: Commissioned
Operational Status: Operational
Coop Number: 310310
WBAN Number: 53878
ATDD Number: 100
Government Property Id: CD0000824632
Power Source: AC
Pair Station Id: 1026
Temperature Sensor Height: null
NWSLI: FLTN7
NOAA Region: Southeast
Temperature Sensor[1]
Manufacturer: Thermometrics
Model: PRT
Calibration Formula: T=C0+C1*V+C2*V^2
Serial Number: 293 56
C0: -243.819 -244.057
C1: 232.857 2326.84
C2: 10.9893 1133.62
Temperature Sensor[2]
Manufacturer: Thermometrics
Model: PRT
Calibration Formula: T=C0+C1*V+C2*V^2
Serial Number: 114 105
C0: -244.578 -244.288
C1: 233.654 2329.93
C2: 10.8217 1120.28
Temperature Sensor[3]
Manufacturer: Thermometrics
Model: PRT
Calibration Formula: T=C0+C1*V+C2*V^2
Serial Number: 128 414
C0: -244.365 -243.419
C1: 233.098 2317.02
C2: 11.1824 1164.68
Wind Speed
Manufacturer: MetOne
Model: 014A
Serial Number: D3065 E7875
Calibration Formula: WS(m/s)=C0+C1*(counts in 10 sec)
C0: .2 .22
C1: .084106 .082668
Primary Rain Gauge
Manufacturer: Geonor
Model: T-200B3W
Calibration Formula: mm=(C1*(Hz-C0)+C2*(Hz-C0)^2)*10
Wind Shield: SDFIR & Alt
Transducer[1]
Model: T-200B Sensor, 600mm
Serial Number: 22401
C0: -1048.8
C1: 1.6842e-2
C2: 9.2175e-6
Transducer[2]
Model: T-200B Sensor, 600mm
Serial Number: 19902
C0: -1052.6
C1: 1.6550e-2
C2: 9.2236e-6
Transducer[3]
Model: T-200B Sensor, 600mm
Serial Number: 22402
C0: -1065.7
C1: 1.6940e-2
C2: 9.1259e-6
Date Emptied: NA
Date Antifreeze Added: NA
Rain Gauge Depth (mm): 600
Secondary Rain Gauge
Manufacturer: Hydrological Services America
Model: TB3
Serial Number: 00-534
Date Emptied: NA
Solar Radiation
Manufacturer: Kipp & Zonen
Model: SP LITE
Calibration Formula: W/m^2=C0+C1*mvolts
Serial Number: 032411 043060
C0: -6.17114 -1.58727
C1: 11.0982 12.46955
Surface Temperature
Manufacturer: Apogee Instruments
Model: IRTS-P
Calibration Formula: surfaceT IN C=C0+C1*mv
Serial Number: 1346
C0: 0.0
C1: 1.0
Datalogger
Manufacturer: Campbell Scientific
Model: CR23X
Serial Number: 6548 3748
Program Version Number: 1.201 1.303
OS Version Number: 1.18 1.19
Downloaded Data Coverage Begin Date: NA
Downloaded Data Coverage End Date: NA
Charger/Controller
Manufacturer: Campbell Scientific
Model: CH12R
Serial Number: 3168
GOES Transmitter
Manufacturer: Seimac
Model: SAT HDR
Serial Number: 15793
Transmission Time: 00:01:00
Transmission Channel: 93A
Platform Id: CD0255BC
Platform Id Type: GOES
Software EPROM Version: 3.2.4
Antenna Orientation: 167
Antenna Angle: 48
Satellite Assignment: E
Aspirated Shield[1]
Manufacturer: MetOne
Model: 076B
Serial Number: A5069
Aspirated Shield[2]
Manufacturer: MetOne
Model: 076B
Serial Number: A3954
Aspirated Shield[3]
Manufacturer: MetOne
Model: 076B
Serial Number: A3640
Wetness
Manufacturer: Vaisala
Model: DRD11A
Serial Number: Z38325
Relative Humidity
Manufacturer: Campbell Scientific Vaisala
Model: CS500 HMT337
Serial Number: 2040052 B3920004
RH Calibration Formula: RH(%)=C0+C1*mvolts
RH C0: 0.0
RH C1: 1.0
Temp Calibration Formula: T(C)=C0+C1*mvolts
Temp C0: -40.0 -39.783625
Temp C1: 1.0 .21949121