Event Details

Station: KS Manhattan 6 SSW Kansas State University (Konza Prairie Biological Station)
Event Type: Maintenance - Annual (Completed)
Event Date: Wed Mar 07 01:00:00 UTC 2012
Notes: null
EventId: 5151
This display shows all new and previous values for all fields in the database for this station as of the addition of this event.
item approved This event has completed QC
previous event next event
Previous Value (prior to event) New Value (if changed)

General Site Information
Name: Kansas State University (Konza Prairie Biological Station)
State: KS
Location: Manhattan
Vector: 6 SSW
County: Riley
Country: US
Latitude: 39.1027
Longitude: -96.6098
Elevation: 1137
Offset: -6
Timezone: CST
Climate Division: 03
Commission Code: Commissioned
Operational Status: Operational
WBAN Number: 53974
ATDD Number: 144
Government Property Id: CD0000826730
Power Source: AC
Temperature Sensor Height: NA
NWSLI: MKHK1
NOAA Region: South
Temperature Sensor[1]
Manufacturer: Thermometrics
Model: PRT
Calibration Formula: T=C0+C1*V+C2*V^2
Serial Number: 809
C0: -243.94
C1: .23255
C2: 1.1311e-5
Temperature Sensor[2]
Manufacturer: Thermometrics
Model: PRT
Calibration Formula: T=C0+C1*V+C2*V^2
Serial Number: 1114
C0: -243.61
C1: .23231
C2: 1.1232e-5
Temperature Sensor[3]
Manufacturer: Thermometrics
Model: PRT
Calibration Formula: T=C0+C1*V+C2*V^2
Serial Number: 661 1007
C0: -243.96 -243.43
C1: .23284 .23210
C2: 1.1074e-5 1.1286e-5
Wind Speed
Manufacturer: MetOne
Model: 014A
Serial Number: C3906 M7876
Calibration Formula: WS(m/s)=C0+C1*(counts in 10 sec)
C0: .22
C1: .08644 .08447
Primary Rain Gauge
Manufacturer: Geonor
Model: T-200B3W
Calibration Formula: mm=(C1*(Hz-C0)+C2*(Hz-C0)^2)*10
Wind Shield: SDFIR & Alt
Transducer[1]
Model: T-200B Sensor, 600mm
Serial Number: 37108
C0: -1057.2
C1: 1.7536e-2
C2: 9.3895e-6
Transducer[2]
Model: T-200B Sensor, 600mm
Serial Number: 21502
C0: -1036.7
C1: 1.5939e-2
C2: 9.0309e-6
Transducer[3]
Model: T-200B Sensor, 600mm
Serial Number: 22202
C0: -1057.2
C1: 1.6733e-2
C2: 9.1071e-6
Date Emptied: 20110324 20120306
Date Antifreeze Added: 20110324 20120307
Rain Gauge Depth (mm): 600
Secondary Rain Gauge
Manufacturer: Hydrological Services America
Model: TB3 - Heated
Serial Number: 03-337
Date Emptied: NA 20120306
Solar Radiation
Manufacturer: Kipp & Zonen
Model: SP LITE
Calibration Formula: W/m^2=C0+C1*mvolts
Serial Number: 042755 042748
C0: -9.30148 -14.73831
C1: 13.076 13.26535
Surface Temperature
Manufacturer: Apogee Instruments
Model: IRTS-P SI 111
Calibration Formula: surfaceT IN C=C0+C1*mv slope = mC2 * BodyT^2 + mC1 * BodyT + mC0;b = bC2 * BodyT^2 + bC1 * BodyT + bC0;SBTempK = BodyT + 273.15;TargTempK = ((SBTempK^4) + slope * TargmV + b)^0.25;SurfTCorr IN C= TargTempK - 273.15
Serial Number: 1605 3200
mC2: null 53388.3
mC1: null 8371980
mC0: null 1356910000
bC2: null 19991.9
bC1: null -291124
bC0: null -5760690
Datalogger
Manufacturer: Campbell Scientific
Model: CR3000
Serial Number: 6500 5053
Program Version Number: 2.402 2.412
OS Version Number: std 21 std 24
Downloaded Data Coverage Begin Date: 20100503 20120105
Downloaded Data Coverage End Date: 20110324 20120306
Charger/Controller
Manufacturer: None
Model: Direct Connect
Serial Number: NA
Compact Flash Module
Manufacturer: Campbell Scientific
Model: NL115
Serial Number: 7790 6079
GOES Transmitter
Manufacturer: Forest Technology Systems
Model: TX312
Serial Number: 2390
Transmission Time: 00:13:40
Transmission Channel: 180
Platform Id: CD0076A4
Platform Id Type: GOES
Software EPROM Version: 3.06
Antenna Orientation: 231
Antenna Angle: 30
Satellite Assignment: W
Aspirated Shield[1]
Manufacturer: MetOne
Model: 076B
Serial Number: A3638
Aspirated Shield[2]
Manufacturer: MetOne
Model: 076B
Serial Number: A3966
Aspirated Shield[3]
Manufacturer: MetOne
Model: 076B
Serial Number: E5610
Wetness
Manufacturer: Vaisala
Model: DRD11A
Serial Number: Z47114
Relative Humidity
Manufacturer: Vaisala
Model: HMT337
Serial Number: D3810039
RH Calibration Formula: RH(%)=C0+C1*mvolts
RH C0: 0.0
RH C1: 0.1
Temp Calibration Formula: T(C)=C0+C1*mvolts
Temp C0: -39.838
Temp C1: .21969
Soil Plot[1]
Surface Description: Low prairie grass
Soil Probe[1]
Installation Depth (cm): 5
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190519
Soil Description: Black sticky loam
Soil Bulk Density (g/cm^3): 1.297
Soil Probe[2]
Installation Depth (cm): 10
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190518
Soil Description: Black sticky loam
Soil Bulk Density (g/cm^3): 1.266
Soil Probe[3]
Installation Depth (cm): 20
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190517
Soil Description: Hard and sticky reddish clay
Soil Bulk Density (g/cm^3): 1.374
Soil Probe[4]
Installation Depth (cm): 50
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190516
Soil Description: Hard and sticky reddish clay
Soil Bulk Density (g/cm^3): 1.271
Soil Probe[5]
Installation Depth (cm): 100
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190515 204469
Soil Description: Hard and sticky reddish clay
Soil Bulk Density (g/cm^3): 1.257
Soil Plot[2]
Surface Description: Low prairie grass
Soil Probe[1]
Installation Depth (cm): 5
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190505
Soil Description: Black sticky loam
Soil Bulk Density (g/cm^3): 1.166
Soil Probe[2]
Installation Depth (cm): 10
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190509
Soil Description: Black sticky loam
Soil Bulk Density (g/cm^3): 1.291
Soil Probe[3]
Installation Depth (cm): 20
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190508
Soil Description: Hard and sticky reddish clay
Soil Bulk Density (g/cm^3): 1.372
Soil Probe[4]
Installation Depth (cm): 50
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190507 204470
Soil Description: Hard and sticky reddish clay
Soil Bulk Density (g/cm^3): 1.406
Soil Probe[5]
Installation Depth (cm): 100
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190506 204481
Soil Description: Hard and sticky reddish clay
Soil Bulk Density (g/cm^3): 1.312
Soil Plot[3]
Surface Description: Low prairie grass
Soil Probe[1]
Installation Depth (cm): 5
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190514
Soil Description: Black sticky loam
Soil Bulk Density (g/cm^3): 1.270
Soil Probe[2]
Installation Depth (cm): 10
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190510
Soil Description: Black sticky loam
Soil Bulk Density (g/cm^3): 1.206
Soil Probe[3]
Installation Depth (cm): 20
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190513
Soil Description: Hard and sticky reddish clay
Soil Bulk Density (g/cm^3): 1.310
Soil Probe[4]
Installation Depth (cm): 50
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190512 204473
Soil Description: Hard and sticky reddish clay
Soil Bulk Density (g/cm^3): 1.200
Soil Probe[5]
Installation Depth (cm): 100
Manuacturer: Stevens Water Monitoring Systems, Inc.
Model: Hydra Probe II SDI-12
Serial Number: 190511 204474
Soil Description: Hard and sticky reddish clay
Soil Bulk Density (g/cm^3): 1.435