Event Details

Station: HI Hilo 5 S University of Hawaii Waiakea Experiment Station
Event Type: Datalogger Door Open - No Action
Event Date: Fri Mar 18 23:00:00 UTC 2011
Notes: Datalogger program adjusted slightly to change the time the pump runs when the Primary Rain Gauge is full (depths rose and fell during this visit)
EventId: 4554
This display shows all new and previous values for all fields in the database for this station as of the addition of this event.
previous event next event
Previous Value (prior to event) New Value (if changed)

General Site Information
Name: University of Hawaii Waiakea Experiment Station
State: HI
Location: Hilo
Vector: 5 S
County: Hawaii
Country: US
Latitude: 19.6450
Longitude: -155.0827
Elevation: 622
Offset: -10
Timezone: HST
Climate Division: 06
Commission Code: Experimental
Operational Status: Operational
WBAN Number: 21515
ATDD Number: 179
Government Property Id: CD0001279374
Power Source: SOLAR
Temperature Sensor Height: NA
NWSLI: WEXH1
NOAA Region: Pacific
Temperature Sensor[1]
Manufacturer: Thermometrics
Model: PRT
Calibration Formula: T=C0+C1*V+C2*V^2
Serial Number: 922
C0: -243.41
C1: .23217
C2: 1.1220e-5
Temperature Sensor[2]
Manufacturer: Thermometrics
Model: PRT
Calibration Formula: T=C0+C1*V+C2*V^2
Serial Number: 1132
C0: -243.38
C1: .23196
C2: 1.1416e-5
Temperature Sensor[3]
Manufacturer: Thermometrics
Model: PRT
Calibration Formula: T=C0+C1*V+C2*V^2
Serial Number: 1134
C0: -243.30
C1: .23178
C2: 1.1491e-5
Wind Speed
Manufacturer: MetOne
Model: 014A
Serial Number: D3061
Calibration Formula: WS(m/s)=C0+C1*(counts in 10 sec)
C0: .25
C1: .08282
Primary Rain Gauge
Manufacturer: Geonor
Model: T-200B3W
Calibration Formula: mm=(C1*(Hz-C0)+C2*(Hz-C0)^2)*10
Wind Shield: Double Alter
Transducer[1]
Model: T-200B Sensor, 600mm
Serial Number: 18502
C0: -1044.9
C1: 1.6550e-2
C2: 9.1274e-6
Transducer[2]
Model: T-200B Sensor, 600mm
Serial Number: 24001
C0: -1059.0
C1: 1.7144e-2
C2: 9.1336e-6
Transducer[3]
Model: T-200B Sensor, 600mm
Serial Number: 24502
C0: -1051.7
C1: 1.6773e-2
C2: 9.0556e-6
Date Emptied: 20110315
Date Antifreeze Added: NA
Rain Gauge Depth (mm): 600
Secondary Rain Gauge
Manufacturer: Hydrological Services America
Model: TB3
Serial Number: 04-533
Date Emptied: NA
Solar Radiation
Manufacturer: Kipp & Zonen
Model: SP LITE
Calibration Formula: W/m^2=C0+C1*mvolts
Serial Number: 042760
C0: -4.68612
C1: 14.51615
Surface Temperature
Manufacturer: Apogee Instruments
Model: IRTS-P
Calibration Formula: surfaceT IN C=C0+C1*mv
Serial Number: 1754
C0: 0.0
C1: 1.0
Datalogger
Manufacturer: Campbell Scientific
Model: CR3000
Serial Number: 5054
Program Version Number: 2.404
OS Version Number: std 21
Downloaded Data Coverage Begin Date: 20091202
Downloaded Data Coverage End Date: 20110314
Compact Flash Module
Manufacturer: Campbell Scientific
Model: NL115
Serial Number: 6071
GOES Transmitter
Manufacturer: Forest Technology Systems
Model: TX312
Serial Number: 1888
Transmission Time: 00:06:20
Transmission Channel: 94A
Platform Id: CD07410A
Platform Id Type: GOES
Software EPROM Version: 3.06
Antenna Orientation: 133
Antenna Angle: 58
Satellite Assignment: W
Aspirated Shield[1]
Manufacturer: MetOne
Model: 076B
Serial Number: D3158
Aspirated Shield[2]
Manufacturer: MetOne
Model: 076B
Serial Number: D3186
Aspirated Shield[3]
Manufacturer: MetOne
Model: 076B
Serial Number: D3175
Wetness
Manufacturer: Vaisala
Model: DRD11A
Serial Number: Z43205
Relative Humidity
Manufacturer: Vaisala
Model: HMT337
Serial Number: F4060107
RH Calibration Formula: RH(%)=C0+C1*mvolts
RH C0: 0.0
RH C1: 0.1
Temp Calibration Formula: T(C)=C0+C1*mvolts
Temp C0: -39.828
Temp C1: .21991