AZ Amado 23 W
FWS, Buenos Aires National Wildlife Refuge
Period of record Sep 26 2010 — Aug 01 2013
USRCRN station

Sensor Monitoring Data

This page contains detailed sensor data used by CRN personnel in monitoring the performance of individual sensors. The data on this page is not intended for casual public use.


Aug 01 2013 5:00 PM MDT
[Aug 01 2013 23:00 UTC]
left arrowPrev Next right arrow
Temperature (°C)
Sensor #1 Sensor #2 Sensor #3 Calculated
16:05 29.9 29.9 29.9 29.86
16:10 29.5 29.5 29.5 29.52
16:15 29.2 29.2 29.2 29.21
16:20 28.9 28.9 28.9 28.86
16:25 29.6 29.6 29.6 29.56
16:30 28.9 28.8 28.8 28.78
16:35 28.6 28.5 28.5 28.54
16:40 27.6 27.5 27.5 27.49
16:45 28.0 28.0 28.0 28.0
16:50 27.8 27.7 27.7 27.73
16:55 27.7 27.6 27.6 27.64
17:00 27.8 27.7 27.7 27.74
Hour Average 28.576
Hour Min (*) 27.5 27.5 27.5 27.49
Hour Max (*) 30.3 30.4 30.3 30.34
Hour Std Dev 0.86 0.88 0.87

Plot 3 Temp Sensors Temp Sensors
Plot Calculated Temp Calculated Temp
Plot 3 Temps + 2 Fans 3 Temps + 2 Fans
TopPrecipitation / Wetness
Wire #1
Depth (mm)
Wire #2
Depth (mm)
Wire #3
Depth (mm)
Wet #1 Wet #2 Calculated
Precip (mm)
16:05 145.8 148.3 150.3 1199 2955 0.0
16:10 145.8 148.3 150.3 1199 2955 0.0
16:15 145.8 148.3 150.3 1203 2953 0.0
16:20 145.8 148.3 150.3 1204 2953 0.0
16:25 145.8 148.3 150.3 1204 2954 0.0
16:30 145.8 148.3 150.3 1204 2953 0.0
16:35 145.8 148.3 150.3 1205 2923 0.0
16:40 145.8 148.3 150.3 1206 2950 0.0
16:45 145.8 148.3 150.3 1208 2951 0.0
16:50 145.8 148.3 150.3 1208 2950 0.0
16:55 145.8 148.3 150.3 1208 2949 0.0
17:00 145.8 148.3 150.3 1211 2949 0.0
Hourly Total 0.0

Plot Gauge Depths Wire Depths + Wetness
Plot Calculated Precip Calculated Precip
TopDiagnostic Data

Fan Speed (rpm)

Fan #1 Fan #2
115.6 0.0

Plot Fans Fan Speeds

Battery Voltages

GOES Transmitter GOES Transmitter
Under Full Load
13.38 13.00

Plot Battery Voltages Battery Voltages

Other Diagnostics

Value
Minutes Datalogger Door Was Open 0.00
Reference Resistor Average 1499.7
Datalogger Signature 618.6
Geonor Inlet Max Temp (°C) 39.92
Precip Gauge Heater Flag Bit Field 0
Door Flag Bit Field 0
Transmitter RF Forward Power 40.0
Transmitter RF Reflected Power 13.0
Datalogger Program Version Number 6.101
Transmitted Year 2013
Transmitted Julian Day 213
Transmitted UTC Time (End of Hour) 2300
Transmitted Longitude -111.44
Transmitted Latitude 31.691
End of File -6666

Plot Datalogger Door Open Datalogger Door Open
Plot Diagnostic Temps Diagnostic Temps


(*) Note regarding temperature values: the station datalogger polls each of the three temperature sensors once every 10 seconds, and keeps a running average of the last 30 of these 10-second samples. This "running 5-minute average" is computed every 10-seconds throughout the hour, for a total of 360 times. The temperature values reported by the station and shown above are the running 5-minute averages from the end of each of the 12 5-minute periods during the hour, and the mininum, maxium, and standard deviation of all 360 5-minute averages. Since the minimum and maximum are computed from all 360 5-minute averages, not just the 12 values shown above, the minimum may occasionally be less than, or the maximum greater than, the minimum and maximum of the 12 5-minute values shown. Back to Temperature