CO Eagle 13 SSE
Sylvan Lake State Park
Period of record Jul 17 2010 — Apr 19 2014
USRCRN station

Sensor Monitoring Data


Nov 30 2012 4:00 PM MST
Nov 30 4:00 PM LST, Nov 30 23:00 UTC
left arrowPrev Next right arrow
Temperature (°C)
LST Sensor #1 Sensor #2 Sensor #3 Calculated UTC
15:05 8.4 8.4 8.4 8.4 22:05
15:10 8.4 8.4 8.4 8.4 22:10
15:15 8.4 8.4 8.4 8.4 22:15
15:20 8.2 8.2 8.2 8.2 22:20
15:25 8.1 8.1 8.1 8.1 22:25
15:30 8.0 8.1 8.0 8.0 22:30
15:35 8.0 8.0 8.0 8.0 22:35
15:40 7.9 8.0 7.9 7.9 22:40
15:45 7.8 7.8 7.8 7.8 22:45
15:50 7.4 7.4 7.4 7.4 22:50
15:55 6.3 6.3 6.3 6.3 22:55
16:00 6.0 6.0 6.0 6.0 23:00
Hour Average 7.7
Hour Min (*) 6.0 6.0 6.0 6.0
Hour Max (*) 8.7 8.7 8.7 8.7
Hour Std Dev 0.78 0.78 0.77

Plot 3 Temp Sensors Temp Sensors
Plot Calculated Temp Calculated Temp
Plot 3 Temps + 2 Fans 3 Temps + 2 Fans
TopPrecipitation / Wetness
LST Wire #1
Depth (mm)
Wire #2
Depth (mm)
Wire #3
Depth (mm)
Wet #1 Wet #2 Calculated
Precip (mm)
UTC
15:05 376.0 371.2 375.6 1274 2956 0.0 22:05
15:10 376.0 371.3 375.6 1274 2956 0.0 22:10
15:15 376.0 371.2 375.7 1274 2956 0.0 22:15
15:20 376.1 371.2 375.7 1274 2955 0.0 22:20
15:25 376.0 371.3 375.6 1270 2955 0.0 22:25
15:30 376.1 371.2 375.6 1238 2954 0.0 22:30
15:35 376.1 371.2 375.6 1220 2950 0.0 22:35
15:40 376.1 371.2 375.6 1218 2954 0.0 22:40
15:45 376.1 371.2 375.6 1215 2954 0.0 22:45
15:50 376.1 371.2 375.6 1210 2954 0.0 22:50
15:55 376.1 371.3 375.4 1205 2953 0.0 22:55
16:00 376.0 371.3 375.2 1199 2953 0.0 23:00
Hourly Total 0.0

Plot Gauge Depths Wire Depths + Wetness
Plot Calculated Precip Calculated Precip
TopDiagnostic Data

Fan Speed (rpm)

Fan #1 Fan #2
119.1 0.0

Plot Fans Fan Speeds

Battery Voltages

GOES Transmitter GOES Transmitter
Under Full Load
13.47 12.80

Plot Battery Voltages Battery Voltages

Other Diagnostics

Value
Minutes Datalogger Door Was Open 0.00
Reference Resistor Average 1499.7
Datalogger Signature 1954.5
Geonor Inlet Max Temp (°C) 10.01
Precip Gauge Heater Flag Bit Field 0
Door Flag Bit Field 0
Transmitter RF Forward Power 40.0
Transmitter RF Reflected Power 17.0
Datalogger Program Version Number 6.101
Transmitted Year 2012
Transmitted Julian Day 335
Transmitted UTC Time (End of Hour) 2300
Transmitted Longitude -106.73
Transmitted Latitude 39.483
End of File -6666

Plot Datalogger Door Open Datalogger Door Open
Plot Diagnostic Temps Diagnostic Temps


(*) Note regarding temperature values: the station datalogger polls each of the three temperature sensors once every 10 seconds, and keeps a running average of the last 30 of these 10-second samples. This "running 5-minute average" is computed every 10-seconds throughout the hour, for a total of 360 times. The temperature values reported by the station and shown above are the running 5-minute averages from the end of each of the 12 5-minute periods during the hour, and the mininum, maxium, and standard deviation of all 360 5-minute averages. Since the minimum and maximum are computed from all 360 5-minute averages, not just the 12 values shown above, the minimum may occasionally be less than, or the maximum greater than, the minimum and maximum of the 12 5-minute values shown. Back to Temperature