AZ Kayenta 16 WSW
NPS, Navajo National Monument
Period of record Aug 18 2010 — Apr 17 2014
USRCRN station

Sensor Monitoring Data


Nov 14 2012 2:00 PM MST
Nov 14 2:00 PM LST, Nov 14 21:00 UTC
left arrowPrev Next right arrow
Temperature (°C)
LST Sensor #1 Sensor #2 Sensor #3 Calculated UTC
13:05 10.8 10.8 10.8 10.8 20:05
13:10 11.0 10.9 11.0 11.0 20:10
13:15 10.5 10.5 10.5 10.5 20:15
13:20 11.7 11.7 11.7 11.7 20:20
13:25 11.2 11.2 11.2 11.2 20:25
13:30 11.8 11.7 11.8 11.8 20:30
13:35 11.7 11.7 11.7 11.7 20:35
13:40 11.4 11.4 11.4 11.4 20:40
13:45 11.5 11.4 11.5 11.5 20:45
13:50 11.6 11.6 11.6 11.6 20:50
13:55 11.7 11.7 11.7 11.7 20:55
14:00 11.3 11.3 11.3 11.3 21:00
Hour Average 11.3
Hour Min (*) 10.4 10.4 10.4 10.4
Hour Max (*) 11.8 11.8 11.8 11.8
Hour Std Dev 0.49 0.50 0.50

Plot 3 Temp Sensors Temp Sensors
Plot Calculated Temp Calculated Temp
Plot 3 Temps + 2 Fans 3 Temps + 2 Fans
TopPrecipitation / Wetness
LST Wire #1
Depth (mm)
Wire #2
Depth (mm)
Wire #3
Depth (mm)
Wet #1 Wet #2 Calculated
Precip (mm)
UTC
13:05 253.3 252.1 249.5 1327 2988 0.0 20:05
13:10 253.3 252.1 249.5 1328 2989 0.0 20:10
13:15 253.3 252.1 249.5 1327 2989 0.0 20:15
13:20 253.3 252.1 249.5 1288 2988 0.0 20:20
13:25 253.3 252.1 249.5 1288 2989 0.0 20:25
13:30 253.3 252.1 249.5 1288 2961 0.0 20:30
13:35 253.3 252.1 249.5 1288 2989 0.0 20:35
13:40 253.3 252.1 249.5 1285 2989 0.0 20:40
13:45 253.3 252.1 249.5 1285 2989 0.0 20:45
13:50 253.3 252.1 249.5 1285 2989 0.0 20:50
13:55 253.3 252.1 249.5 1285 2990 0.0 20:55
14:00 253.3 252.1 249.5 1285 2990 0.0 21:00
Hourly Total 0.0

Plot Gauge Depths Wire Depths + Wetness
Plot Calculated Precip Calculated Precip
TopDiagnostic Data

Fan Speed (rpm)

Fan #1 Fan #2
123.5 0.0

Plot Fans Fan Speeds

Battery Voltages

GOES Transmitter GOES Transmitter
Under Full Load
14.06 13.70

Plot Battery Voltages Battery Voltages

Other Diagnostics

Value
Minutes Datalogger Door Was Open 0.00
Reference Resistor Average 1499.8
Datalogger Signature 1741.2
Geonor Inlet Max Temp (°C) 18.53
Precip Gauge Heater Flag Bit Field 0
Door Flag Bit Field 0
Transmitter RF Forward Power 40.0
Transmitter RF Reflected Power 18.0
Datalogger Program Version Number 6.101
Transmitted Year 2012
Transmitted Julian Day 319
Transmitted UTC Time (End of Hour) 2100
Transmitted Longitude -110.54
Transmitted Latitude 36.682
End of File -6666

Plot Datalogger Door Open Datalogger Door Open
Plot Diagnostic Temps Diagnostic Temps


(*) Note regarding temperature values: the station datalogger polls each of the three temperature sensors once every 10 seconds, and keeps a running average of the last 30 of these 10-second samples. This "running 5-minute average" is computed every 10-seconds throughout the hour, for a total of 360 times. The temperature values reported by the station and shown above are the running 5-minute averages from the end of each of the 12 5-minute periods during the hour, and the mininum, maxium, and standard deviation of all 360 5-minute averages. Since the minimum and maximum are computed from all 360 5-minute averages, not just the 12 values shown above, the minimum may occasionally be less than, or the maximum greater than, the minimum and maximum of the 12 5-minute values shown. Back to Temperature