NM Socorro 17 WSW
FS, Cibola National Forest (Magdalena Ridge Observatory)
Period of record Jun 25 2010 — Jun 01 2014
USRCRN station
closed iconStation Closed

Sensor Monitoring Data


Oct 14 2013 9:00 PM MDT
Oct 14 8:00 PM LST, Oct 15 03:00 UTC
left arrowPrev Next right arrow
Temperature (°C)
LST Sensor #1 Sensor #2 Sensor #3 Calculated UTC DST
19:05 4.4 4.3 4.4 4.35 02:05 20:05
19:10 4.3 4.3 4.3 4.3 02:10 20:10
19:15 4.2 4.2 4.2 4.2 02:15 20:15
19:20 4.3 4.2 4.2 4.21 02:20 20:20
19:25 4.4 4.3 4.3 4.33 02:25 20:25
19:30 4.0 3.9 3.9 3.93 02:30 20:30
19:35 3.6 3.5 3.6 3.55 02:35 20:35
19:40 3.4 3.4 3.4 3.39 02:40 20:40
19:45 3.3 3.3 3.3 3.28 02:45 20:45
19:50 3.1 3.0 3.0 3.03 02:50 20:50
19:55 3.2 3.2 3.2 3.16 02:55 20:55
20:00 3.1 3.0 3.0 3.02 03:00 21:00
Hour Average 3.729
Hour Min (*) 3.0 3.0 3.0 2.99
Hour Max (*) 4.4 4.4 4.4 4.35
Hour Std Dev 0.53 0.53 0.53

Plot 3 Temp Sensors Temp Sensors
Plot Calculated Temp Calculated Temp
Plot 3 Temps + 2 Fans 3 Temps + 2 Fans
TopPrecipitation / Wetness
LST Wire #1
Depth (mm)
Wire #2
Depth (mm)
Wire #3
Depth (mm)
Wet #1 Wet #2 Calculated
Precip (mm)
UTC DST
19:05 285.5 282.9 293.2 1160 3006 0.0 02:05 20:05
19:10 285.5 283.0 293.2 1161 3006 0.0 02:10 20:10
19:15 285.5 283.0 293.2 1160 3006 0.0 02:15 20:15
19:20 285.5 283.0 293.3 1160 3006 0.0 02:20 20:20
19:25 285.5 283.0 293.3 1160 3006 0.0 02:25 20:25
19:30 285.5 283.0 293.3 1159 3002 0.0 02:30 20:30
19:35 285.5 283.0 293.2 1160 3006 0.0 02:35 20:35
19:40 285.5 283.0 293.3 1159 3006 0.0 02:40 20:40
19:45 285.5 283.0 293.2 1159 3006 0.0 02:45 20:45
19:50 285.5 283.0 293.3 1159 3006 0.0 02:50 20:50
19:55 285.5 283.0 293.3 1158 3006 0.0 02:55 20:55
20:00 285.5 283.0 293.3 1159 3006 0.0 03:00 21:00
Hourly Total 0.0

Plot Gauge Depths Wire Depths + Wetness
Plot Calculated Precip Calculated Precip
TopDiagnostic Data

Fan Speed (rpm)

Fan #1 Fan #2
114.4 0.0

Plot Fans Fan Speeds

Battery Voltages

GOES Transmitter GOES Transmitter
Under Full Load
12.85 12.50

Plot Battery Voltages Battery Voltages

Other Diagnostics

Value
Minutes Datalogger Door Was Open 0.00
Reference Resistor Average 1499.8
Datalogger Signature 5750.5
Geonor Inlet Max Temp (°C) 3.47
Precip Gauge Heater Flag Bit Field 0
Door Flag Bit Field 0
Transmitter RF Forward Power 40.0
Transmitter RF Reflected Power 22.0
Datalogger Program Version Number 6.101
Transmitted Year 2013
Transmitted Julian Day 288
Transmitted UTC Time (End of Hour) 300
Transmitted Longitude -107.18
Transmitted Latitude 33.979
End of File -6666

Plot Datalogger Door Open Datalogger Door Open
Plot Diagnostic Temps Diagnostic Temps


(*) Note regarding temperature values: the station datalogger polls each of the three temperature sensors once every 10 seconds, and keeps a running average of the last 30 of these 10-second samples. This "running 5-minute average" is computed every 10-seconds throughout the hour, for a total of 360 times. The temperature values reported by the station and shown above are the running 5-minute averages from the end of each of the 12 5-minute periods during the hour, and the mininum, maxium, and standard deviation of all 360 5-minute averages. Since the minimum and maximum are computed from all 360 5-minute averages, not just the 12 values shown above, the minimum may occasionally be less than, or the maximum greater than, the minimum and maximum of the 12 5-minute values shown. Back to Temperature