NM Mills 6 WSW
FS, Kiowa and Rita Blanca National Grasslands near Mills
Period of record May 12 2010 — Jul 31 2013
USRCRN station

Sensor Monitoring Data

This page contains detailed sensor data used by CRN personnel in monitoring the performance of individual sensors. The data on this page is not intended for casual public use.


Jul 31 2013 12:00 AM MDT
[Jul 31 2013 06:00 UTC]
left arrowPrev Next right arrow
Temperature (°C)
Sensor #1 Sensor #2 Sensor #3 Calculated
23:05 22.1 22.1 22.1 22.1
23:10 22.1 22.1 22.1 22.08
23:15 22.0 22.0 22.0 22.0
23:20 21.8 21.8 21.8 21.77
23:25 21.7 21.7 21.7 21.69
23:30 21.8 21.8 21.7 21.77
23:35 22.3 22.3 22.3 22.29
23:40 22.5 22.5 22.4 22.46
23:45 22.5 22.5 22.5 22.52
23:50 22.5 22.5 22.4 22.45
23:55 22.5 22.5 22.5 22.53
00:00 22.5 22.5 22.5 22.48
Hour Average 22.178
Hour Min (*) 21.7 21.7 21.6 21.66
Hour Max (*) 22.5 22.5 22.5 22.53
Hour Std Dev 0.31 0.31 0.31

Plot 3 Temp Sensors Temp Sensors
Plot Calculated Temp Calculated Temp
Plot 3 Temps + 2 Fans 3 Temps + 2 Fans
TopPrecipitation / Wetness
Wire #1
Depth (mm)
Wire #2
Depth (mm)
Wire #3
Depth (mm)
Wet #1 Wet #2 Calculated
Precip (mm)
23:05 216.0 213.0 211.1 1149 2927 0.0
23:10 216.0 213.0 211.1 1148 2927 0.0
23:15 216.0 212.9 211.1 1149 2928 0.0
23:20 216.0 212.9 211.1 1147 2927 0.0
23:25 216.0 212.9 211.1 1147 2864 0.0
23:30 216.0 212.9 211.1 1148 2927 0.0
23:35 216.0 213.0 211.1 1146 2928 0.0
23:40 216.0 213.0 211.1 1148 2929 0.0
23:45 216.0 213.0 211.1 1146 2927 0.0
23:50 216.0 213.0 211.1 1147 2928 0.0
23:55 216.0 213.0 211.1 1146 2928 0.0
00:00 216.0 213.0 211.1 1145 2928 0.0
Hourly Total 0.0

Plot Gauge Depths Wire Depths + Wetness
Plot Calculated Precip Calculated Precip
TopDiagnostic Data

Fan Speed (rpm)

Fan #1 Fan #2
112.7 0.0

Plot Fans Fan Speeds

Battery Voltages

GOES Transmitter GOES Transmitter
Under Full Load
12.73 12.30

Plot Battery Voltages Battery Voltages

Other Diagnostics

Value
Minutes Datalogger Door Was Open 0.00
Reference Resistor Average 1499.8
Datalogger Signature 2061.4
Geonor Inlet Max Temp (°C) 24.83
Precip Gauge Heater Flag Bit Field 0
Door Flag Bit Field 0
Transmitter RF Forward Power 40.0
Transmitter RF Reflected Power 20.0
Datalogger Program Version Number 6.101
Transmitted Year 2013
Transmitted Julian Day 212
Transmitted UTC Time (End of Hour) 600
Transmitted Longitude -104.35
Transmitted Latitude 36.060
End of File -6666

Plot Datalogger Door Open Datalogger Door Open
Plot Diagnostic Temps Diagnostic Temps


(*) Note regarding temperature values: the station datalogger polls each of the three temperature sensors once every 10 seconds, and keeps a running average of the last 30 of these 10-second samples. This "running 5-minute average" is computed every 10-seconds throughout the hour, for a total of 360 times. The temperature values reported by the station and shown above are the running 5-minute averages from the end of each of the 12 5-minute periods during the hour, and the mininum, maxium, and standard deviation of all 360 5-minute averages. Since the minimum and maximum are computed from all 360 5-minute averages, not just the 12 values shown above, the minimum may occasionally be less than, or the maximum greater than, the minimum and maximum of the 12 5-minute values shown. Back to Temperature