AZ Coolidge 5 W
NPS, Casa Grande Ruins National Monument
Period of record Feb 27 2010 — May 23 2013
USRCRN station

Sensor Monitoring Data

This page contains detailed sensor data used by CRN personnel in monitoring the performance of individual sensors. The data on this page is not intended for casual public use.


May 23 2013 8:00 AM MDT
[May 23 2013 14:00 UTC]
left arrowPrev Next right arrow
Temperature (°C)
Sensor #1 Sensor #2 Sensor #3 Calculated
07:05 18.8 18.8 18.8 18.8
07:10 18.9 18.9 18.9 18.9
07:15 19.6 19.6 19.6 19.6
07:20 19.6 19.6 19.6 19.6
07:25 19.7 19.7 19.6 19.7
07:30 19.7 19.7 19.6 19.7
07:35 20.5 20.5 20.5 20.5
07:40 21.6 21.6 21.6 21.6
07:45 22.3 22.3 22.2 22.3
07:50 22.7 22.7 22.7 22.7
07:55 23.1 23.1 23.0 23.1
08:00 23.3 23.3 23.2 23.3
Hour Average 20.8
Hour Min (*) 18.8 18.7 18.7 18.7
Hour Max (*) 23.3 23.3 23.2 23.3
Hour Std Dev 1.61 1.61 1.61

Plot 3 Temp Sensors Temp Sensors
Plot Calculated Temp Calculated Temp
Plot 3 Temps + 2 Fans 3 Temps + 2 Fans
TopPrecipitation / Wetness
Wire #1
Depth (mm)
Wire #2
Depth (mm)
Wire #3
Depth (mm)
Wet #1 Wet #2 Calculated
Precip (mm)
07:05 140.6 141.6 140.7 1119 2896 0.0
07:10 140.6 141.6 140.7 1119 2896 0.0
07:15 140.6 141.6 140.7 1120 2896 0.0
07:20 140.6 141.6 140.7 1120 2897 0.0
07:25 140.6 141.6 140.7 1121 2791 0.0
07:30 140.6 141.6 140.7 1122 2898 0.0
07:35 140.6 141.6 140.7 1123 2898 0.0
07:40 140.6 141.5 140.7 1126 2899 0.0
07:45 140.6 141.5 140.7 1128 2900 0.0
07:50 140.6 141.5 140.7 1131 2901 0.0
07:55 140.6 141.5 140.7 1134 2903 0.0
08:00 140.6 141.5 140.7 1138 2904 0.0
Hourly Total 0.0

Plot Gauge Depths Wire Depths + Wetness
Plot Calculated Precip Calculated Precip
TopDiagnostic Data

Fan Speed (rpm)

Fan #1 Fan #2
107.4 0.0

Plot Fans Fan Speeds

Battery Voltages

GOES Transmitter GOES Transmitter
Under Full Load
12.53 12.00

Plot Battery Voltages Battery Voltages

Other Diagnostics

Value
Minutes Datalogger Door Was Open 0.00
Reference Resistor Average 1499.8
Datalogger Signature 2296.7
Geonor Inlet Max Temp (°C) 29.34
Precip Gauge Heater Flag Bit Field 0
Door Flag Bit Field 0
Transmitter RF Forward Power 40.0
Transmitter RF Reflected Power 18.0
Datalogger Program Version Number 6.101
Transmitted Year 2013
Transmitted Julian Day 143
Transmitted UTC Time (End of Hour) 1400
Transmitted Longitude -111.53
Transmitted Latitude 32.991
End of File -6666

Plot Datalogger Door Open Datalogger Door Open
Plot Diagnostic Temps Diagnostic Temps


(*) Note regarding temperature values: the station datalogger polls each of the three temperature sensors once every 10 seconds, and keeps a running average of the last 30 of these 10-second samples. This "running 5-minute average" is computed every 10-seconds throughout the hour, for a total of 360 times. The temperature values reported by the station and shown above are the running 5-minute averages from the end of each of the 12 5-minute periods during the hour, and the mininum, maxium, and standard deviation of all 360 5-minute averages. Since the minimum and maximum are computed from all 360 5-minute averages, not just the 12 values shown above, the minimum may occasionally be less than, or the maximum greater than, the minimum and maximum of the 12 5-minute values shown. Back to Temperature