NM Reserve 1 W
FS, Gila National Forest (Reserve Ranger Station)
Period of record Jul 10 2009 — Jun 01 2014
USRCRN station
closed iconStation Closed

Sensor Monitoring Data


Feb 21 2014 10:00 PM MST
Feb 21 10:00 PM LST, Feb 22 05:00 UTC
left arrowPrev Next right arrow
Temperature (°C)
LST Sensor #1 Sensor #2 Sensor #3 Calculated UTC
21:05 7.4 7.3 7.4 7.36 04:05
21:10 6.9 6.9 6.9 6.9 04:10
21:15 6.7 6.6 6.6 6.64 04:15
21:20 6.4 6.3 6.4 6.35 04:20
21:25 6.0 6.0 6.0 6.01 04:25
21:30 5.9 5.9 5.9 5.9 04:30
21:35 5.7 5.7 5.7 5.73 04:35
21:40 5.7 5.6 5.6 5.64 04:40
21:45 4.8 4.8 4.8 4.81 04:45
21:50 4.9 4.9 4.9 4.93 04:50
21:55 4.8 4.7 4.8 4.75 04:55
22:00 4.6 4.5 4.6 4.56 05:00
Hour Average 5.798
Hour Min (*) 4.6 4.5 4.6 4.56
Hour Max (*) 8.1 8.0 8.1 8.05
Hour Std Dev 0.90 0.91 0.91

Plot 3 Temp Sensors Temp Sensors
Plot Calculated Temp Calculated Temp
Plot 3 Temps + 2 Fans 3 Temps + 2 Fans
TopPrecipitation / Wetness
LST Wire #1
Depth (mm)
Wire #2
Depth (mm)
Wire #3
Depth (mm)
Wet #1 Wet #2 Calculated
Precip (mm)
UTC
21:05 364.7 363.0 361.2 1138 2976 0.0 04:05
21:10 364.7 363.0 361.2 1137 2977 0.0 04:10
21:15 364.7 363.0 361.2 1138 2977 0.0 04:15
21:20 364.7 362.9 361.2 1137 2966 0.0 04:20
21:25 364.7 362.9 361.2 1137 2977 0.0 04:25
21:30 364.7 362.9 361.2 1136 2978 0.0 04:30
21:35 364.7 362.9 361.3 1137 2978 0.0 04:35
21:40 364.7 362.9 361.2 1136 2978 0.0 04:40
21:45 364.7 362.8 361.3 1135 2978 0.0 04:45
21:50 364.7 362.8 361.3 1136 2978 0.0 04:50
21:55 364.7 362.8 361.3 1135 2978 0.0 04:55
22:00 364.7 362.8 361.3 1136 2978 0.0 05:00
Hourly Total 0.0

Plot Gauge Depths Wire Depths + Wetness
Plot Calculated Precip Calculated Precip
TopDiagnostic Data

Fan Speed (rpm)

Fan #1 Fan #2
96.5 0.0

Plot Fans Fan Speeds

Battery Voltages

GOES Transmitter GOES Transmitter
Under Full Load
12.54 12.10

Plot Battery Voltages Battery Voltages

Other Diagnostics

Value
Minutes Datalogger Door Was Open 0.00
Reference Resistor Average 1499.7
Datalogger Signature 1132.7
Geonor Inlet Max Temp (°C) 29.13
Precip Gauge Heater Flag Bit Field 0
Door Flag Bit Field 0
Transmitter RF Forward Power 40.0
Transmitter RF Reflected Power 17.0
Datalogger Program Version Number 6.101
Transmitted Year 2014
Transmitted Julian Day 53
Transmitted UTC Time (End of Hour) 500
Transmitted Longitude -108.77
Transmitted Latitude 33.714
End of File -6666

Plot Datalogger Door Open Datalogger Door Open
Plot Diagnostic Temps Diagnostic Temps


(*) Note regarding temperature values: the station datalogger polls each of the three temperature sensors once every 10 seconds, and keeps a running average of the last 30 of these 10-second samples. This "running 5-minute average" is computed every 10-seconds throughout the hour, for a total of 360 times. The temperature values reported by the station and shown above are the running 5-minute averages from the end of each of the 12 5-minute periods during the hour, and the mininum, maxium, and standard deviation of all 360 5-minute averages. Since the minimum and maximum are computed from all 360 5-minute averages, not just the 12 values shown above, the minimum may occasionally be less than, or the maximum greater than, the minimum and maximum of the 12 5-minute values shown. Back to Temperature