AL Highland Home 2 S
Highland Home
Period of record Dec 02 2008 — Mar 30 2015
USRCRN station
alert iconExperimental Station

Sensor Monitoring Data


Mar 30 2015 8:00 AM CDT
Mar 30 7:00 AM LST, Mar 30 13:00 UTC
left arrowPrev Next right arrow
Temperature (°C)
LST Sensor #1 Sensor #2 Sensor #3 Calculated UTC DST
06:05 13.4 13.4 13.4 13.39 12:05 07:05
06:10 13.4 13.4 13.4 13.41 12:10 07:10
06:15 13.5 13.5 13.5 13.49 12:15 07:15
06:20 13.5 13.5 13.6 13.54 12:20 07:20
06:25 13.6 13.6 13.7 13.63 12:25 07:25
06:30 13.7 13.7 13.7 13.71 12:30 07:30
06:35 13.8 13.8 13.8 13.8 12:35 07:35
06:40 13.9 13.9 13.9 13.89 12:40 07:40
06:45 14.0 14.1 14.1 14.05 12:45 07:45
06:50 14.1 14.1 14.2 14.14 12:50 07:50
06:55 14.3 14.2 14.3 14.25 12:55 07:55
07:00 14.4 14.3 14.4 14.37 13:00 08:00
Hour Average 13.802
Hour Min (*) 13.3 13.3 13.4 13.34
Hour Max (*) 14.4 14.3 14.4 14.37
Hour Std Dev 0.33 0.32 0.32

Plot 3 Temp Sensors Temp Sensors
Plot Calculated Temp Calculated Temp
Plot 3 Temps + 2 Fans 3 Temps + 2 Fans
TopPrecipitation / Wetness
LST Wire #1
Depth (mm)
Wire #2
Depth (mm)
Wire #3
Depth (mm)
Wet #1 Wet #2 Calculated
Precip (mm)
UTC DST
06:05 317.2 306.4 310.3 1149 2939 0.0 12:05 07:05
06:10 317.2 306.4 310.3 1150 2939 0.0 12:10 07:10
06:15 317.2 306.5 310.3 1150 2940 0.0 12:15 07:15
06:20 317.2 306.5 310.3 1150 2937 0.0 12:20 07:20
06:25 317.2 306.5 310.3 1153 2940 0.0 12:25 07:25
06:30 317.2 306.5 310.3 1160 2941 0.0 12:30 07:30
06:35 317.2 306.5 310.3 1159 2941 0.0 12:35 07:35
06:40 317.3 306.5 310.3 1160 2943 0.0 12:40 07:40
06:45 317.3 306.5 310.4 1156 2945 0.0 12:45 07:45
06:50 317.3 306.5 310.4 1150 2948 0.0 12:50 07:50
06:55 317.3 306.5 310.4 1150 2947 0.0 12:55 07:55
07:00 317.3 306.5 310.4 1152 2948 0.0 13:00 08:00
Hourly Total 0.0

Plot Gauge Depths Wire Depths + Wetness
Plot Calculated Precip Calculated Precip
TopDiagnostic Data

Fan Speed (rpm)

Fan #1 Fan #2
104.5 0.0

Plot Fans Fan Speeds

Battery Voltages

GOES Transmitter GOES Transmitter
Under Full Load
12.70 12.30

Plot Battery Voltages Battery Voltages

Other Diagnostics

Value
Minutes Datalogger Door Was Open 0.00
Reference Resistor Average 1499.9
Datalogger Signature 5541.6
Geonor Inlet Max Temp (°C) 16.60
Precip Gauge Heater Flag Bit Field 0
Door Flag Bit Field 0
Transmitter RF Forward Power 40.0
Transmitter RF Reflected Power 13.0
Datalogger Program Version Number 5.101
Transmitted Year 2015
Transmitted Julian Day 89
Transmitted UTC Time (End of Hour) 1300
Transmitted Longitude -86.31
Transmitted Latitude 31.915
End of File -6666

Plot Datalogger Door Open Datalogger Door Open
Plot Diagnostic Temps Diagnostic Temps


(*) Note regarding temperature values: the station datalogger polls each of the three temperature sensors once every 10 seconds, and keeps a running average of the last 30 of these 10-second samples. This "running 5-minute average" is computed every 10-seconds throughout the hour, for a total of 360 times. The temperature values reported by the station and shown above are the running 5-minute averages from the end of each of the 12 5-minute periods during the hour, and the mininum, maxium, and standard deviation of all 360 5-minute averages. Since the minimum and maximum are computed from all 360 5-minute averages, not just the 12 values shown above, the minimum may occasionally be less than, or the maximum greater than, the minimum and maximum of the 12 5-minute values shown. Back to Temperature