AL Thomasville 2 S
Thomasville
Period of record Jan 18 2008 — Nov 28 2014
USRCRN station
alert iconExperimental Station

Sensor Monitoring Data


Nov 24 2012 1:00 PM CST
Nov 24 1:00 PM LST, Nov 24 19:00 UTC
left arrowPrev Next right arrow
Temperature (°C)
LST Sensor #1 Sensor #2 Sensor #3 Calculated UTC
12:05 10.9 10.9 10.9 10.9 18:05
12:10 11.4 11.5 11.4 11.4 18:10
12:15 11.6 11.7 11.7 11.7 18:15
12:20 11.7 11.7 11.7 11.7 18:20
12:25 11.4 11.5 11.5 11.5 18:25
12:30 11.8 11.8 11.8 11.8 18:30
12:35 11.8 11.8 11.8 11.8 18:35
12:40 11.9 11.9 11.9 11.9 18:40
12:45 12.1 12.1 12.1 12.1 18:45
12:50 11.7 11.7 11.7 11.7 18:50
12:55 11.8 11.9 11.9 11.9 18:55
13:00 12.1 12.1 12.1 12.1 19:00
Hour Average 11.7
Hour Min (*) 10.7 10.8 10.8 10.8
Hour Max (*) 12.1 12.1 12.1 12.1
Hour Std Dev 0.48 0.47 0.42

Plot 3 Temp Sensors Temp Sensors
Plot Calculated Temp Calculated Temp
Plot 3 Temps + 2 Fans 3 Temps + 2 Fans
TopPrecipitation / Wetness
LST Wire #1
Depth (mm)
Wire #2
Depth (mm)
Wire #3
Depth (mm)
Wet #1 Wet #2 Calculated
Precip (mm)
UTC
12:05 266.8 265.2 263.0 1225 2971 0.0 18:05
12:10 266.8 265.2 262.8 1224 2971 0.0 18:10
12:15 266.8 265.2 262.8 1224 2969 0.0 18:15
12:20 266.8 265.2 262.8 1225 2970 0.0 18:20
12:25 266.8 265.2 262.8 1225 2968 0.0 18:25
12:30 266.8 265.2 262.9 1225 2972 0.0 18:30
12:35 266.8 265.2 262.8 1223 2973 0.0 18:35
12:40 266.8 265.2 262.8 1222 2974 0.0 18:40
12:45 266.8 265.2 262.8 1222 2966 0.0 18:45
12:50 266.8 265.2 262.8 1223 2971 0.0 18:50
12:55 266.8 265.2 262.8 1221 2970 0.0 18:55
13:00 266.8 265.2 262.8 1222 2971 0.0 19:00
Hourly Total 0.0

Plot Gauge Depths Wire Depths + Wetness
Plot Calculated Precip Calculated Precip
TopDiagnostic Data

Fan Speed (rpm)

Fan #1 Fan #2
110.1 0.0

Plot Fans Fan Speeds

Battery Voltages

GOES Transmitter GOES Transmitter
Under Full Load
13.46 13.00

Plot Battery Voltages Battery Voltages

Other Diagnostics

Value
Minutes Datalogger Door Was Open 0.00
Reference Resistor Average 1499.9
Datalogger Signature 1837.3
Geonor Inlet Max Temp (°C) 19.34
Precip Gauge Heater Flag Bit Field 0
Door Flag Bit Field 0
Transmitter RF Forward Power 40.0
Transmitter RF Reflected Power 11.0
Datalogger Program Version Number 5.101
Transmitted Year 2012
Transmitted Julian Day 329
Transmitted UTC Time (End of Hour) 1900
Transmitted Longitude -87.74
Transmitted Latitude 31.881
End of File -6666

Plot Datalogger Door Open Datalogger Door Open
Plot Diagnostic Temps Diagnostic Temps


(*) Note regarding temperature values: the station datalogger polls each of the three temperature sensors once every 10 seconds, and keeps a running average of the last 30 of these 10-second samples. This "running 5-minute average" is computed every 10-seconds throughout the hour, for a total of 360 times. The temperature values reported by the station and shown above are the running 5-minute averages from the end of each of the 12 5-minute periods during the hour, and the mininum, maxium, and standard deviation of all 360 5-minute averages. Since the minimum and maximum are computed from all 360 5-minute averages, not just the 12 values shown above, the minimum may occasionally be less than, or the maximum greater than, the minimum and maximum of the 12 5-minute values shown. Back to Temperature