AL Thomasville 2 S
Thomasville
Period of record Jan 18 2008 — Jan 24 2015
USRCRN station
alert iconExperimental Station

Sensor Monitoring Data


Jan 24 2015 9:00 PM CST
Jan 24 9:00 PM LST, Jan 25 03:00 UTC
left arrowPrev Next right arrow
Temperature (°C)
LST Sensor #1 Sensor #2 Sensor #3 Calculated UTC
20:05 1.6 1.6 1.6 1.58 02:05
20:10 1.7 1.7 1.7 1.67 02:10
20:15 1.5 1.5 1.6 1.52 02:15
20:20 1.3 1.3 1.4 1.32 02:20
20:25 1.1 1.1 1.2 1.12 02:25
20:30 1.1 1.1 1.1 1.1 02:30
20:35 1.4 1.3 1.4 1.35 02:35
20:40 1.1 1.1 1.1 1.12 02:40
20:45 1.0 0.9 1.0 0.96 02:45
20:50 0.7 0.7 0.8 0.72 02:50
20:55 0.9 0.8 0.9 0.85 02:55
21:00 0.7 0.7 0.7 0.7 03:00
Hour Average 1.168
Hour Min (*) 0.7 0.7 0.7 0.7
Hour Max (*) 1.7 1.7 1.7 1.68
Hour Std Dev 0.33 0.34 0.34

Plot 3 Temp Sensors Temp Sensors
Plot Calculated Temp Calculated Temp
Plot 3 Temps + 2 Fans 3 Temps + 2 Fans
TopPrecipitation / Wetness
LST Wire #1
Depth (mm)
Wire #2
Depth (mm)
Wire #3
Depth (mm)
Wet #1 Wet #2 Calculated
Precip (mm)
UTC
20:05 110.9 123.3 118.0 1179 2904 0.0 02:05
20:10 110.9 123.3 118.0 1179 2905 0.0 02:10
20:15 110.9 123.3 117.9 1179 2905 0.0 02:15
20:20 110.9 123.3 117.9 1179 2906 0.0 02:20
20:25 110.9 123.3 117.9 1179 2904 0.0 02:25
20:30 110.9 123.3 117.8 1178 2904 0.0 02:30
20:35 110.9 123.3 117.8 1178 2905 0.0 02:35
20:40 110.9 123.3 117.8 1178 2906 0.0 02:40
20:45 110.9 123.3 117.8 1177 2895 0.0 02:45
20:50 110.9 123.3 117.7 1178 2904 0.0 02:50
20:55 110.9 123.3 117.7 1177 2905 0.0 02:55
21:00 110.9 123.3 117.7 1177 2905 0.0 03:00
Hourly Total 0.0

Plot Gauge Depths Wire Depths + Wetness
Plot Calculated Precip Calculated Precip
TopDiagnostic Data

Fan Speed (rpm)

Fan #1 Fan #2
107.3 0.0

Plot Fans Fan Speeds

Battery Voltages

GOES Transmitter GOES Transmitter
Under Full Load
12.98 12.70

Plot Battery Voltages Battery Voltages

Other Diagnostics

Value
Minutes Datalogger Door Was Open 0.00
Reference Resistor Average 1499.8
Datalogger Signature 1214.2
Geonor Inlet Max Temp (°C) 0.61
Precip Gauge Heater Flag Bit Field 0
Door Flag Bit Field 0
Transmitter RF Forward Power 40.0
Transmitter RF Reflected Power 8.0
Datalogger Program Version Number 5.101
Transmitted Year 2015
Transmitted Julian Day 25
Transmitted UTC Time (End of Hour) 300
Transmitted Longitude -87.73
Transmitted Latitude 31.881
End of File -6666

Plot Datalogger Door Open Datalogger Door Open
Plot Diagnostic Temps Diagnostic Temps


(*) Note regarding temperature values: the station datalogger polls each of the three temperature sensors once every 10 seconds, and keeps a running average of the last 30 of these 10-second samples. This "running 5-minute average" is computed every 10-seconds throughout the hour, for a total of 360 times. The temperature values reported by the station and shown above are the running 5-minute averages from the end of each of the 12 5-minute periods during the hour, and the mininum, maxium, and standard deviation of all 360 5-minute averages. Since the minimum and maximum are computed from all 360 5-minute averages, not just the 12 values shown above, the minimum may occasionally be less than, or the maximum greater than, the minimum and maximum of the 12 5-minute values shown. Back to Temperature