AL Valley Head 1 SSW
Valley Head
Period of record May 04 2006 — Dec 19 2014
USRCRN station
alert iconExperimental Station

Sensor Monitoring Data


Dec 19 2014 11:00 AM CST
Dec 19 11:00 AM LST, Dec 19 17:00 UTC
left arrowPrev Next right arrow
Temperature (°C)
LST Sensor #1 Sensor #2 Sensor #3 Calculated UTC
10:05 3.9 3.8 4.0 3.94 16:05
10:10 4.1 4.0 4.1 4.12 16:10
10:15 4.5 4.4 4.5 4.49 16:15
10:20 4.4 4.3 4.4 4.35 16:20
10:25 4.4 4.3 4.4 4.39 16:25
10:30 4.8 4.7 4.7 4.74 16:30
10:35 5.1 5.0 5.0 5.04 16:35
10:40 5.1 5.0 5.1 5.07 16:40
10:45 5.0 4.9 5.0 5.03 16:45
10:50 5.2 5.2 5.2 5.22 16:50
10:55 5.3 5.2 5.3 5.28 16:55
11:00 5.6 5.5 5.6 5.56 17:00
Hour Average 4.77
Hour Min (*) 3.8 3.7 3.8 3.77
Hour Max (*) 5.6 5.5 5.6 5.56
Hour Std Dev 0.52 0.52 0.51

Plot 3 Temp Sensors Temp Sensors
Plot Calculated Temp Calculated Temp
Plot 3 Temps + 2 Fans 3 Temps + 2 Fans
TopPrecipitation / Wetness
LST Wire #1
Depth (mm)
Wire #2
Depth (mm)
Wire #3
Depth (mm)
Wet #1 Wet #2 Calculated
Precip (mm)
UTC
10:05 87.5 87.8 89.4 1236 2903 0.0 16:05
10:10 87.5 87.8 89.4 1233 2902 0.0 16:10
10:15 87.5 87.8 89.4 1234 2901 0.0 16:15
10:20 87.5 87.8 89.4 1236 2902 0.0 16:20
10:25 87.5 87.8 89.4 1236 2902 0.0 16:25
10:30 87.5 87.8 89.4 1236 2901 0.0 16:30
10:35 87.5 87.8 89.4 1234 2901 0.0 16:35
10:40 87.5 87.8 89.4 1233 2901 0.0 16:40
10:45 87.5 87.8 89.4 1237 2901 0.0 16:45
10:50 87.5 87.8 89.4 1247 2901 0.0 16:50
10:55 87.5 87.8 89.4 1238 2901 0.0 16:55
11:00 87.5 87.8 89.4 1245 2902 0.0 17:00
Hourly Total 0.0

Plot Gauge Depths Wire Depths + Wetness
Plot Calculated Precip Calculated Precip
TopDiagnostic Data

Fan Speed (rpm)

Fan #1 Fan #2
112.3 0.0

Plot Fans Fan Speeds

Battery Voltages

GOES Transmitter GOES Transmitter
Under Full Load
13.73 13.00

Plot Battery Voltages Battery Voltages

Other Diagnostics

Value
Minutes Datalogger Door Was Open 0.00
Reference Resistor Average 1499.8
Datalogger Signature 5279.5
Geonor Inlet Max Temp (°C) 8.25
Precip Gauge Heater Flag Bit Field 0
Door Flag Bit Field 0
Transmitter RF Forward Power 40.0
Transmitter RF Reflected Power 6.0
Datalogger Program Version Number 5.101
Transmitted Year 2014
Transmitted Julian Day 353
Transmitted UTC Time (End of Hour) 1700
Transmitted Longitude -85.61
Transmitted Latitude 34.565
End of File -6666

Plot Datalogger Door Open Datalogger Door Open
Plot Diagnostic Temps Diagnostic Temps


(*) Note regarding temperature values: the station datalogger polls each of the three temperature sensors once every 10 seconds, and keeps a running average of the last 30 of these 10-second samples. This "running 5-minute average" is computed every 10-seconds throughout the hour, for a total of 360 times. The temperature values reported by the station and shown above are the running 5-minute averages from the end of each of the 12 5-minute periods during the hour, and the mininum, maxium, and standard deviation of all 360 5-minute averages. Since the minimum and maximum are computed from all 360 5-minute averages, not just the 12 values shown above, the minimum may occasionally be less than, or the maximum greater than, the minimum and maximum of the 12 5-minute values shown. Back to Temperature